Start practice — 8 questions →
Sample questions
Which of the following is a stated restriction regarding application concentration?
- Do not apply at a concentration lower than 0.03%
- Do not apply at a concentration lower than 0.06%, 0.09%, or 0.125% for horizontal and vertical treatments
- Do not apply more than 0.125% concentration
- Do not apply at a concentration higher than 0.06%
Show answer
The restrictions state: 'NO lo aplique usando una dosis ni concentración INFERIOR al 0.06%, al 0.09% ni al 0.125% para tratamientos horizontales y verticales.'🔗 Source
If you are mixing for a 0.09% finished strength, how much product is needed for 100 gallons of water?
- 39.0 (1 qt + 7 fl oz)
- 59.0 (1 qt + 27 fl oz)
- 117.0 (3 qt + 21 fl oz)
- 78.0 (2 qt + 14 fl oz)
Show answer
The mixing instructions for 0.09% finished strength specify 117.0 (3 qt + 21 fl oz) per 100 gallons.🔗 Source
According to the timing and weather section, when can people return to the treated area?
- Immediately after application
- After 24 hours
- Once the soil has absorbed the final diluted solution of Termidor SC
- After the product has dried on the surface
Show answer
The label states: 'no regresen hasta que el suelo haya absorbido la solución diluida final de Termidor SC.'🔗 Source
For vertical barriers along the interior and exterior perimeter of foundation walls, what is the required rate per 10 linear feet per foot of depth?
- 1.0 a 1.5 galones
- 10.0 galones
- 2 galones
- 20.0 galones
Show answer
The label states the rate for vertical barriers is 2 gallons per 10 linear feet per foot of depth.🔗 Source
When applying horizontal barriers to concrete slabs on the ground or in basements, what is the required application rate?
- 2 galones por cada 10 pies lineales por pie de profundidad
- 1.0 a 1.5 galones por cada 10 pies cuadrados
- 0.4 galones por cada 1.0 gal
- 0.03% de concentración
Show answer
The label specifies a rate of 1.0 to 1.5 gallons per 10 square feet for horizontal barriers on concrete slabs.🔗 Source
When using the trenching method for pre-construction termite treatments, what are the requirements for trench dimensions?
- A minimum depth of 6 inches and a width not exceeding 6 inches
- A depth of 12 inches and a width of 10 inches
- A depth of 6 inches and a width of 12 inches
- A depth no more than 6 inches and a width of 6 inches
Show answer
The label notes that trenches must have a minimum depth of 6 inches (not deeper than the bottom of the footing) and a width not exceeding 6 inches.🔗 Source
To achieve a finished strength of 0.125%, how much product should be mixed per 25 gallons of water?
- 1.6 units
- 19.0 (1 pt + 3 fl oz)
- 39.0 (1 qt + 7 fl oz)
- 39.0 (1 qt + 7 fl oz)
Show answer
The mixing instructions for 0.125% finished strength specify 39.0 (1 qt + 7 fl oz) per 25 gallons.🔗 Source
According to the label, what are the target pests for this product?
- Termitas y otras plagas que atacan la madera
- Solo termitas
- Termitas y hormigas carpinteras
- Termitas y cucarachas
Show answer
The label states the target pests are 'termitas y otras plagas que atacan la madera'.🔗 Source
← All practice exams